One System for All Areas

Water mist systems offer the ideal middle ground between traditional sprinklers and gaseous fire suppression systems and can be used throughout the entire data center. But it’s important to remember: not all water mist-systems are equal. The quality of the suppression medium varies depending on the pressure levels and pump technology used – resulting in significant differences in water consumption and potential damage.
FOGTEC high-pressure water mist systems produce ultra-fine droplets, delivering highly efficient fire suppression while minimizing collateral damage.

Holistic Approach

With just a single pump, you can protect your entire data center – and in some cases, thanks to mobile pump units (FOGTEC SafetyUnit), even multiple buildings.

Cable Ducts

Data Center

Server Hall

Server Hall

Meeting Room

Meeting Room

Offices

Offices

Energy
Storage System

Energy
Storage System

Atrium

Atrium

UPS Room

UPS Room

Generator Room

Generator Room

Technical Room

Technical Room

Water Mist Pump Room

Technical Room

Charging
Station

Charging
Station

Transformer
Room

Transformer
Room

Parking Garage

Parking Garage

Pre-Action Systems
Data Centers

The system is designed as a pre-action setup with single- or double-interlock control. The protected area is divided into suppression zones, each activated via pre-action valves.
All pipework remains dry and unfilled with water until activation. The system triggers based on a two-detector dependency and only after thermal activation of nearby glass bulb nozzles. This ensures the system activates only at the fire’s point of origin, leaving other areas unaffected or minimally impacted.
Thanks to the thermal activation, the risk of false discharge is virtually eliminated.

Water-Based Systems in Comparison
Infografik Comparison
< 20%

of the water volume used by traditional sprinklers is needed by high-pressure water mist systems – drastically reducing water demand and damage.

> 80 %

of water damage can be avoided by using high-pressure water mist instead of traditional sprinkler systems.

High-Pressure Water Mist in the White Space
  • Targeted local application of the extinguishing medium
  • FOGTEC system: approx. 2 liters per nozzle per square meter per minute (could be illustrated as a graphic)
  • High cooling effect protects sensitive equipment
  • Outstanding performance in flushing corrosive substances
  • No pressure relief vents required
  • No need for room enclosure
  • No pre-alarm delays
  • Space-saving design
  • Small pump room footprint
  • Optional containerized pump solutions available
  • Easy expansion to other areas (e.g., technical rooms, public areas, energy storage systems, etc.)
  • Very fast reactivation
  • High system availability

FAQ – Fire Protection for Water Mist in Data Centers

External Content from Brevo
This section contains our newsletter subscription form. To display this content, your consent is required to transfer data to external servers.

More Information

Water Mist in Data Centers

Your email has to be confirmed. Check your inbox!

Your email has to be confirmed. Check your inbox!

Your download is awaiting activation!

"*" indicates required fields

Name*
This field is hidden when viewing the form
This field is hidden when viewing the form